Punching Shear Behaviour of FRP Strengthened Flat Slab With and Without Geo-Grid
Loading...
Files
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The upgradation of the building to satisfy the current demand and to improve the performance of
weaker sections of buildings, requires advanced techniques. In particular the lesser reinforcement
ratio in flat slabs are prone to punching shear failure when the building is upgraded
It is very difficult to increase the percentage of reinforcement in the existing slab. It requires
external strengthening using conventional or advanced technique. The conventional technique
increases the cross sectional size and is time consuming and it also effects the adjacent structures
element performance.
FRP is a proven material in strengthening work. This study is mainly focussed on the use of GFRP
and BFRP in uni-directional and bi-directional to improve the punching shear behaviour of flat
slabs with different reinforcement ratios. In order to reduce the strengthening area required, geo
grid as reinforcement to FRP is also evaluated only using FRP in UD (uni-direction). The load
deflection, stiffness and energy dissipation, crack pattern and failure pattern are the parameters
that are evaluated.
Description
Master of Engineering -Structural Engineering