Abstract
Reinforced concrete is one of the most commonly used construction materials in civil
engineering but its durability problems have been obsessing people. The worst of these
problems is caused by corrosion of steel in concrete, inducing the early deterioration of
concrete infrastructures. Structural deterioration of reinforced concrete structures affected by
corrosion is a gradual process consisting of a few different phases during service life,
including corrosion initiation, concrete cracking, excessive deflection and final collapse due
to loss of structural strength.
Cathodic Protection is a reduction or elimination of corrosion by making the metal a cathode
by impressing a DC current. A new development in repair and rehabilitation of RC structures
is the use of carbon fiber reinforced polymers (CFRP) which provide a barrier layer that is
expected to impede further corrosion of steel and prevents dislodging of concrete cover.
Another important advantage of CFRP could be active protection of structures using CFRP
wraps as anode and the steel rebar as cathode.
The present work investigates protection of the strand achieved by using surface bonded
carbon FRP. The electrically conductive carbon fibre is used as anode while the prestressing
tendon is used as cathode in the present active protection. To initiate initial corrosion in the
specimens, impressed current was passed through the strand. Then, carbon FRP sheets have
been adhesively bonded by using conductive epoxy to the block specimens. Specimens were
exposed to highly corrosive environment for specified time. It is observed that the active
protection technique is very effective in retarding the corrosion of strand.