Numerical Investigation of Crack-Tip Constraint Parameters in Straight Pipes Under Reactor Operating Conditions
Loading...
Files
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
J-R curve is established as fracture toughness for designing critical nuclear components. The
original idea was that a single parameter, J-integral can be used to characterize the crack tip
conditions and one unique fracture toughness curve is sufficient to characterize the material.
However, later on it is realized that J-R curve is geometry dependent for considerable plasticzone
size ahead of crack tip. The influence of crack tip stress triaxiality has been already
emphasized in geometry dependent fracture resistance. Hence, two parameter fracture mechanics
has emerged like J-q, J-Q, J-A2, etc. Due to simplification and applicability over wide range of
loading J-q has been studied extensively for fracture specimens. Very few attempts have been
made for numerical investigation of q in real life components.
In Indian PHWR, PHT piping components are used to transfer hot (300oC) heavy water
under internal pressure to harness the heat from reactor. The material used in piping component
is SA333Gr6, Carbon Steel (CS) material. In the present work, three dimensional finite element
models are prepared for Three Point Bend Bar (TPBB) specimen and straight pipes with different
crack configurations like throughwall and surface cracks. Pipes are simulated under loading of
four point bending. The load is applied monotonically and quasi-statically to study the fracture
behaviour. These pipes are analyzed under internal pressure or elevated temperature. Four point
bending is performed with both of internal pressure and elevated temperature also which is actual
reactor operating conditions for pipes. q and Q parameter are calculated for the TPBB specimen
and pipes. The work also addresses the variation of q and Q for throughwall crack and surface
crack in remaining ligament with deformation level. This data is useful for transferring the
laboratory specimen J-R curve to the component level considering stress triaxiality.