Energy being basic need of a human being, should be utilized efficiently i.e minimum
wastage of energy should be there. Industries are consuming a major portion of electrical
energy in developed as well as developing countries. In industries, 90% above, induction
motors are used to perform the various activities.
Induction motors being the major energy consumer in industry offer opportunities of energy
saving. In plant many induction motors are rewound. This thesis reports the analysis done on
the new and rewound induction motor for its efficiency. Life cycle cost of the new and
rewound motor is analysed based upon its efficiency and other parameters. Comparison
between new and rewound motors is shown. It is found that rewound motor consume 1.5 to 2
times more energy than new motor.
Description
M.E. (Power System and Electric Drives)