Analysis of Ambient Temperature Effect on Blood Viscosity and Blood Pressure Drop

dc.contributor.authorKalia, Raghu
dc.contributor.supervisorSingla, Sunil Kumar
dc.date.accessioned2014-09-09T07:25:58Z
dc.date.available2014-09-09T07:25:58Z
dc.date.issued2014-09-09T07:25:58Z
dc.descriptionME, EIEDen
dc.description.abstractBlood pressure drop in humans considering the effect of ambient temperature variation due to various climatic and environmental changes is such a phenomenon which is still unexplored. By implementing the developed algorithm in the blood pressure measuring devices can improve their performance. In this study, a comparison is made between the blood pressure drop readings for both men and women considering the effect of ambient temperature change and employing various heat transfer modes. For a group of healthy individuals within the age group of 27±4 years, height ranging 170±5 cm and weight 73±5 kg (means±SD), the results presented and discussed here are for both men and women with same height 170.6 cm and weight 73 kg. According to the mathematical model created and after the implementation of the developed algorithm, it is observed that ambient temperature variation certainly affects arterial blood pressure drop in the brachial artery with length 22.22 cm. The range of systolic blood pressure drop values in case of men lies between 2.7561 mmHg to 6.5470 mmHg and the range of diastolic blood pressure drop lies between 0.3802 mmHg to 0.9032 mmHg. For women, the range of systolic blood pressure drop values lies between 2.4996 mmHg to 5.9356 mmHg and for diastolic blood pressure drop, this range lies between 0.40233 mmHg to 0.95539 mmHg. The obtained values for blood pressure drop can be added as a correction factor to the readings presented as final output by the current blood pressure measuring devices in order to obtain the correct systolic and diastolic blood pressure values. Hence, this study is termed as blood pressure drop-correction factor (BPD-CF). This analysis helps to infer about the functioning of the heart and its cardiac cycle.en
dc.format.extent1195822 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/10266/3179
dc.language.isoenen
dc.subjectAnalysisen
dc.subjectAmbient Temperature Effecten
dc.subjectAnalysis of Ambient Temperature Ef Blood Pressure Dropen
dc.titleAnalysis of Ambient Temperature Effect on Blood Viscosity and Blood Pressure Dropen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
3179.pdf
Size:
1.14 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Item-specific license agreed upon to submission
Description: