Abstract
Present work has been carried out to investigate the flow characteristics of refrigerants R-407 C,
R-134a, R-410 A, R-12 and R-404 A flowing through helical capillary tube under adiabatic flow
conditions. The parametric study was conducted by varying operating conditions and geometrical
parameters of the capillary tube. A mathematical model has been developed to predict the
performance of a refrigerant in helical capillary tube under adiabatic flow conditions. The
proposed model can predict the length of the adiabatic helical capillary tube for a given mass
flow rate or the mass flow rate through a given length of capillary tube. A computer program
coded in MATLAB has been developed to compute either length or mass flow rate by fixing
some of parameter. This model also includes the effect of various design parameters, like
capillary tube diameter, capillary tube coil diameter, degree of sub-cooling, evaporator pressure,
inlet pressure, mass flow rate. Thermodynamic and transport property can derived from
advanced property data base such as REFPROP. The mathematical model based on homogenous
two phase flow without considering metastable length has been developed to predict the flow
characteristics of a refrigerant in helical capillary tube for adiabatic flow conditions. A set of
differential equations is obtained by applying the law of conservation of mass, momentum and
energy. These differential equations are solved using finite difference method. Different
correlations for friction factor and viscosity available in the literature are used in the model.
Performance of conventional and non conventional refrigerants can be compared under different
operating conditions. The developed model can be considered as an effective tool for designing
and optimizing capillary tubes working with newer alternative refrigerants. The model is
validated by comparison with the experimental data of Kim et al. (2002) for R-22, R-407C and
R-410A, Zhou and Zhang (2006) for R-22 and Khan et al (2009) for R-134a. The results
obtained from the present model show reasonable agreement with the experimental data. The
proposed model can be used to design helical capillary tubes working with various refrigerants.
Description
M.E. (Thermal Engineering)